Informazioni sul CVE-2023-32735

N/A

CWE ID: CWE-502

Base Score (CVSS): N/A

CVE: CVE-2023-32735

Descrizione: A vulnerability has been identified in SIMATIC STEP 7 Safety V16 (All versions < V16 Update 7), SIMATIC STEP 7 Safety V17 (All versions < V17 Update 7), SIMATIC STEP 7 Safety V18 (All versions < V18 Update 2), SIMATIC STEP 7 V16 (All versions < V16 Update 7), SIMATIC STEP 7 V17 (All versions < V17 Update 7), SIMATIC STEP 7 V18 (All versions < V18 Update 2), SIMATIC WinCC Unified V16 (All versions < V16 Update 7), SIMATIC WinCC Unified V17 (All versions < V17 Update 7), SIMATIC WinCC Unified V18 (All versions < V18 Update 2), SIMATIC WinCC V16 (All versions < V16.7), SIMATIC WinCC V17 (All versions < V17.7), SIMATIC WinCC V18 (All versions < V18 Update 2), SIMOCODE ES V16 (All versions < V16 Update 7), SIMOCODE ES V17 (All versions < V17 Update 7), SIMOCODE ES V18 (All versions < V18 Update 2), SIMOTION SCOUT TIA V5.4 SP1 (All versions), SIMOTION SCOUT TIA V5.4 SP3 (All versions), SIMOTION SCOUT TIA V5.5 SP1 (All versions), SINAMICS Startdrive V16 (All versions), SINAMICS Startdrive V17 (All versions), SINAMICS Startdrive V18 (All versions), SIRIUS Safety ES V17 (All versions < V17 Update 7), SIRIUS Safety ES V18 (All versions < V18 Update 2), SIRIUS Soft Starter ES V17 (All versions < V17 Update 7), SIRIUS Soft Starter ES V18 (All versions < V18 Update 2), Soft Starter ES V16 (All versions < V16 Update 7), TIA Portal Cloud V3.0 (All versions < V18 Update 2). Affected applications do not properly restrict the .NET BinaryFormatter when deserializing hardware configuration profiles. This could allow an attacker to cause a type confusion and execute arbitrary code within the affected application. This is the same issue that exists for .NET BinaryFormatter https://docs.microsoft.com/en-us/visualstudio/code-quality/ca2300.

Vettore di attacco CVSS:3.1/AV:L/AC:L/PR:H/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C

Punteggio CVSS

Il CVSS è un sistema di valutazione che misura la gravità di una vulnerabilità informatica considerando fattori come l’impatto potenziale, la probabilità di attacco e la facilità di esecuzione.

Punteggio Base (calcolato da AziendaSicura): 6.5 (Medium)

Riassunto: Accesso: Local, Privilegi: High, Interazione utente: Required, Confidenzialità: High, Integrità: High, Disponibilità: High.

Dettaglio del Vettore

Metrica Valore Significato Descrizione
Attack Vector (AV) L Local L’attaccante deve avere accesso locale al sistema.
Attack Complexity (AC) L Low L’attacco non richiede condizioni particolari.
Privileges Required (PR) H High Richiede privilegi elevati.
User Interaction (UI) R Required È richiesta l’interazione di un utente.
Scope (S) U Unchanged Il raggio d’azione non cambia.
Confidentiality Impact (C) H High Grave impatto sulla riservatezza.
Integrity Impact (I) H High Grave impatto sull’integrità.
Availability Impact (A) H High Rende il sistema inutilizzabile.
Exploit Code Maturity (E) P Proof-of-Concept Esistono PoC.
Remediation Level (RL) O Official Fix Patch ufficiale disponibile.
Report Confidence (RC) C Confirmed Confermata ufficialmente.

Riferimenti esterni

Prodotti interessati

  • Siemens – SIMATIC STEP 7 Safety V16
  • Siemens – SIMATIC STEP 7 Safety V17
  • Siemens – SIMATIC STEP 7 Safety V18
  • Siemens – SIMATIC STEP 7 V16
  • Siemens – SIMATIC STEP 7 V17
  • Siemens – SIMATIC STEP 7 V18
  • Siemens – SIMATIC WinCC Unified V16
  • Siemens – SIMATIC WinCC Unified V17
  • Siemens – SIMATIC WinCC Unified V18
  • Siemens – SIMATIC WinCC V16
  • Siemens – SIMATIC WinCC V17
  • Siemens – SIMATIC WinCC V18
  • Siemens – SIMOCODE ES V16
  • Siemens – SIMOCODE ES V17
  • Siemens – SIMOCODE ES V18
  • Siemens – SIMOTION SCOUT TIA V5.4 SP1
  • Siemens – SIMOTION SCOUT TIA V5.4 SP3
  • Siemens – SIMOTION SCOUT TIA V5.5 SP1
  • Siemens – SINAMICS Startdrive V16
  • Siemens – SINAMICS Startdrive V17
  • Siemens – SINAMICS Startdrive V18
  • Siemens – SIRIUS Safety ES V17
  • Siemens – SIRIUS Safety ES V18
  • Siemens – SIRIUS Soft Starter ES V17
  • Siemens – SIRIUS Soft Starter ES V18
  • Siemens – Soft Starter ES V16
  • Siemens – TIA Portal Cloud V3.0

Relazioni con altri prodotti

Produttore:Siemens
Prodotto: SIMOCODE ES V16
Anno: 2023
CWE: CWE-502
CVSS: 0.0

Produttore:Siemens
Prodotto: Soft Starter ES V16
Anno: 2023
CWE: CWE-502
CVSS: 0.0

Produttore:Siemens
Prodotto: SIMATIC WinCC V16
Anno: 2023
CWE: CWE-502
CVSS: 0.0

Produttore:Siemens
Prodotto: SIMATIC WinCC V17
Anno: 2023
CWE: CWE-502
CVSS: 0.0

Produttore:Siemens
Prodotto: SIMATIC STEP 7 V16
Anno: 2023
CWE: CWE-502
CVSS: 0.0

Produttore:Siemens
Prodotto: SIMATIC STEP 7 V17
Anno: 2023
CWE: CWE-502
CVSS: 0.0

Produttore:Siemens
Prodotto: SIMATIC STEP 7 V18
Anno: 2023
CWE: CWE-502
CVSS: 0.0

Produttore:Siemens
Prodotto: SIMATIC STEP 7 Safety V16
Anno: 2023
CWE: CWE-502
CVSS: 0.0

Produttore:Siemens
Prodotto: SIMATIC STEP 7 Safety V17
Anno: 2023
CWE: CWE-502
CVSS: 0.0

Produttore:Siemens
Prodotto: SIMATIC STEP 7 Safety V18
Anno: 2023
CWE: CWE-502
CVSS: 0.0

Produttore:Siemens
Prodotto: SIMATIC WinCC Unified V16
Anno: 2023
CWE: CWE-502
CVSS: 0.0

Produttore:Siemens
Prodotto: SIMATIC WinCC Unified V17
Anno: 2023
CWE: CWE-502
CVSS: 0.0

Produttore:Siemens
Prodotto: SIMATIC WinCC Unified V18
Anno: 2023
CWE: CWE-502
CVSS: 0.0

Produttore:Siemens
Prodotto: SIMATIC WinCC V18
Anno: 2023
CWE: CWE-502
CVSS: 0.0

Produttore:Siemens
Prodotto: SIMOCODE ES V17
Anno: 2023
CWE: CWE-502
CVSS: 0.0

Produttore:Siemens
Prodotto: SIMOCODE ES V18
Anno: 2023
CWE: CWE-502
CVSS: 0.0

Produttore:Siemens
Prodotto: SIMOTION SCOUT TIA V5.4 SP1
Anno: 2023
CWE: CWE-502
CVSS: 0.0

Produttore:Siemens
Prodotto: SIMOTION SCOUT TIA V5.4 SP3
Anno: 2023
CWE: CWE-502
CVSS: 0.0

Produttore:Siemens
Prodotto: SIMOTION SCOUT TIA V5.5 SP1
Anno: 2023
CWE: CWE-502
CVSS: 0.0

Produttore:Siemens
Prodotto: SINAMICS Startdrive V16
Anno: 2023
CWE: CWE-502
CVSS: 0.0

Produttore:Siemens
Prodotto: SINAMICS Startdrive V17
Anno: 2023
CWE: CWE-502
CVSS: 0.0

Produttore:Siemens
Prodotto: SINAMICS Startdrive V18
Anno: 2023
CWE: CWE-502
CVSS: 0.0

Produttore:Siemens
Prodotto: SIRIUS Safety ES V17
Anno: 2023
CWE: CWE-502
CVSS: 0.0

Produttore:Siemens
Prodotto: SIRIUS Safety ES V18
Anno: 2023
CWE: CWE-502
CVSS: 0.0

Produttore:Siemens
Prodotto: SIRIUS Soft Starter ES V17
Anno: 2023
CWE: CWE-502
CVSS: 0.0

Produttore:Siemens
Prodotto: SIRIUS Soft Starter ES V18
Anno: 2023
CWE: CWE-502
CVSS: 0.0

Produttore:Siemens
Prodotto: TIA Portal Cloud V3.0
Anno: 2023
CWE: CWE-502
CVSS: 0.0

Ulteriori risorse disponibili